Aluminium Oppose Blade Damper
Regulates Air volume from particular collar while balancing Air conditioning system. Generally installed behind grilles or diffusers. Oppose blade operation for better regulation of air volume.
FEATURES
- Extruded Aluminium Construction
- Nylon Gear for smooth Operation
MODELS
- AP-AL-OBD Aluminium Oppose Blade Damper

Round Volume Control Damper
Round Volume Control Dampers, are installed in branches of air distribution ducts to regulate air volume in different branches to achieve rough balancing of the system. The fine balancing is being carried out at the individual Grilles & Diffuser outlet.
FEATURES
- G.I. Steel Construction
MODELS
- AP-RDD Round Volume Control Damper as per requirement.

Motorised Volume Control Damper
Motorised Volume Control Dampers, are installed in branches of air distribution ducts operated motorised, to regulate air volume in different branches to achieve rough balancing of the system. The fine balancing is being carried out at the individual grilles & diffuser outlet.
FEATURES
- Extruded Aluminium or G.I. Sheet Steel
- Gear or Linkage Driven
- Nylon Bushing for smooth operation
MODELS
- AP-VCD-GI-MO Motorised Operated G.I. Construction
- AP-VCD-AL-MO Motorised Operated Aluminium Construction

Manual Volume Control Damper
Manual Volume Control Dampers, are installed in branches of air distribution ducts operated manually, to regulate air volume in different branches to achieve rough balancing of the system. The fine balancing is being carried out at the individual grilles & diffuser outlet.
FEATURES
- Extruded Aluminium Construction
- Gear or Linkage Driven.
- Nylon Bushing for smooth operation
MODELS
- AP-VCD-AL/GI Manual Operated Aluminium Construction

Fire Damper with Fusible Link-Manual
Fire Damper with Fusible Link are installed in or near the wall or floor, at the point of duct penetration, to retain the integrity and fire rating of a wall or floor whether it is a ducted or open-plenum return application. A fire damper closes once the duct temperature reaches at fire rating temperature level to melt a fusible link.
FEATURES
- Heavy Duty 16 Guage Construction
- NON UL-555 Certificate Fusible Link
- Standard Sleeve Length of 350mm & 600mm optional
MODELS
- AP-FD-FL Fusible Link Operation
- AP-FD-FL-SL Fusible Link Operation with Sleeve

Fire Damper-Motorised
Fire dampers: An automatic device installed in ducts and air transfer opening of an air distribution or smoke control system that is controlled by a smoke detection system and/or fire alarms. It is designed to resist the passage of smoke through the heating, ventilation, and air conditioning system or from a fire-rated separation area. It is operated by either a factory-installed electric or a pneumatic actuator.
FEATURES
- Heavy Duty 16 Guage Construction
- Standard Sleeve Length of 350 mm & 600 mm optional
MODELS
- AP-FD-MO Motorised Operation
- AP-FD-MO-SL Motorised Operation with Sleeve